Ge-68 Line Sources

Ge-68 line sources are double layered tubes and made of high quality stainless steel. Each line source is sealed on its ends by the process of precise argon welding. Thanks to the argon welding process, the possibility of activity leakage is eliminated, ensuring safe use of line sources.

Source related information including product code, isotope type, activity, serial number and production date is permanently marked with laser for traceability.

Ge-68 Cylindrical Phantom

Ge-68 Cylindrical phantoms are used for 2D and 3D normalization and in test images of PET and PET-CT systems. Radioactive element is uniformly filled in the cylindrical cast. Each cylindrical phantom manufactured is checked with a PET-CT scanner to ensure high quality.

The results of quality control image files are available upon request.

Siemens Healthineers

System Model
Product Code
Product Type
Isotope
Activity (SI)
Activity (Non-SI)
Quantity
Replacement Period
BIOGRAPH
Initial Set-up & Annual Replacement
FNT1010
Phantom
Ge-68
44 MBq
1.2 mCi
1
1 Year
CBK1020
Line Source
Ge-68
37 MBq
1 mCi
2
1 Year
TST1030
Test Tube
Ge-68
5.5 kBq
0.15 uCi
1
1 Year
BIOGRAPH PICO
Initial Set-up & Annual Replacement
FNT1014
Phantom
Ge-68
74 MBq
2 mCi
1
1 Year
CBK1020
Line Source
Ge-68
37 MBq
1 mCi
2
1 Year
TST1031
Test Tube
Ge-68
15 kBq
0.15 uCi
1
1 Year
BIOGRAPH TRUE V & mCT & Horizon
Initial Set-up & Annual Replacement
FNT1012
Long Phantom
Ge-68
74 MBq
2 mCi
1
1 Year
CBK1020
Line Source
Ge-68
37 MBq
1 mCi
1
1 Year
TST1031
Test Tube
Ge-68
15 kBq
0.41 uCi
1
1 Year
Initial Set-up & Annual Replacement
FNT1013
Long Phantom
Ge-68
92.5 MBq
2.51 mCi
1
1 Year
CBK1020
Line Source
Ge-68
46.25 MBq
1.24 mCi
1
1 Year
TST1031
Test Tube
Ge-68
15 kBq
0.41 uCi
1
1 Year
BIOGRAPH 450 Vision
Initial Set-up & Annual Replacement
FNT1012
Long Phantom
Ge-68
92.5 MBq
2.51 mCi
1
1 Year
CBK1020
Line Source
Ge-68
46.25 MBq
1.24 mCi
1
1 Year
TST1031
Test Tube
Ge-68
15 kBq
0.41 uCi
1
1 Year
BIOGRAPH 600 Vision
Initial Set-up & Annual Replacement
FNT1015
Long Phantom
Ge-68
111 MBq
3
1
1 Year
CBK1020
Line Source
Ge-68
46.25 MBq
1.24 mCi
2
1 Year
TST1031
Test Tube
Ge-68
15 kBq
0.41 uCi
1
1 Year
BIOGRAPH mMR
Initial Set-up & Annual Replacement
FNT1015
Long Phantom
Ge-68
111 MBq
3 mCi
1
1 Year
CBK1025
Line Source
Ge-68
55 MBq
1.5 mCi
4
1 Year
TST1031
Test Tube
Ge-68
15 kBq
0.41 uCi
1
1 Year
Intevo xSpect w/Peaking
Initial Set-up & Annual Replacement
SPT1290
Spot-Line
Co-57
117 MBq
3 mCi
1
1 Year
SPT1291
Spot Peaking
Co-57
1.49 MBq
40 uCi
1
1 Year
Intevo Symbia
Initial Set-up & Annual Replacement
CBK1920
Line Source
Gd-153
370 MBq
10 mCi
1
1 Year
CBK1220
Line Source
Co-57
1.85 MBq
50 uCi
1
1 Year

GE Healthcare

System Model
Discovery ST/VCT
Discovery 560 FX
Discovery 560
Discovery 600/610
Discovery 690 & 690 Elite
Discovery 710 & 710 Elite
Discovery LS
Discovery IQ, MI & DR (3R-4R-5R)
Discovery IQ, MI & DR (2R)
Signa PET/MR
Product Code
CBK2020
CBK2021
CBK2022
CBK2022
FNT2090
CBK2021
FNT2090
CBK2021
FNT2090
CBK2023
CBK2024
FNT2010
FNT2090
FNT2010
FNT2091
FNT2010
FNT2090
FNT2091
SPH2093
Product Type
Line Source
Line Source
Line Source
Line Source
VQC Phantom
Line Source
VQC Phantom
Line Source
VQC Phantom
Line Source
Line Source
Annulus Phantom
VQC Phantom
Annulus Phantom
10cm VQC Phantom
Annulus Phantom
VQC Phantom
10cm VQC Phantom
Sphere
Isotope
Ge-68
Ge-68
Ge-68
Ge-68
Ge-68
Ge-68
Ge-68
Ge-68
Ge-68
Ge-68
Ge-68
Ge-68
Ge-68
Ge-68
Ge-68
Ge-68
Ge-68
Ge-68
Ge-68
Activity (SI)
55 MBq
18.5 MBq
10 MBq
10 MBq
3.5 MBq
18.5 MBq
3.5 MBq
18.5 MBq
3.5 MBq
60 MBq
400 MBq
55 MBq
3.5 MBq
55 MBq
3.5 MBq
55 MBq
3.5 MBq
3.5 MBq
0,70 MBq
Activity (Non-SI)
1.49 mCi
0.5 mCi
0.27 mCi
0.27 mCi
0.09 mCi
0.5 mCi
0.09 mCi
0.5 mCi
0.09 mCi
1.62 mCi
10.81 mCi
1.5 mCi
0.09 mCi
1.5 mCi
0.09 mCi
1.5 mCi
0.09 mCi
0.09 mCi
19 uCi
Quantity
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
3
Replacement Period
1 Year
1 Year
1 Year
1 Year
1 Year
1 Year
1 Year
1 Year
1 Year
2 Years
6-9 Months
1 Year
1 Year
1 Year
1 Year
1 Year
1 Year
1 Year
2 Year

Contact Us